1. Download and Install Dell OpenManage for Windows. You will only need command line toolsat this point, Web-based management tools / SNMP tools can wait.
2. After installing Dell OpenManage go to Windows command line and paste (and push enter) this command to see your DIMMs status:
omreport chassis memory
The result should be similar to:
Memory Information
Health : Critical
Memory Redundancy
Fail Over State          : Inactive
Redundancy Configuration : Disabled
Attributes of Memory Array(s)
Attributes of Memory Array(s)
Location           : System Board or Motherboard
Use                : System Memory
Installed Capacity : 16384  MB
Maximum Capacity   : 65280  MB
Slots Available    : 8
Slots Used         : 8
Error Correction   : Multibit ECC
Total of Memory Array(s)
Total Installed Capacity                     : 16384  MB
Total Installed Capacity Available to the OS : 16046  MB
Total Maximum Capacity                       : 65280  MB
Details of Memory Array 1
Index          : 0
Status         : Critical
Connector Name : DIMM1
Type           : DDR2 FB-DIMM - Synchronous
Size           : 2048  MB
Index          : 1
Status         : Ok
Connector Name : DIMM2
Type           : DDR2 FB-DIMM - Synchronous
Size           : 2048  MB
<------------- CUT -------------->
Index          : 7
Status         : Ok
Connector Name : DIMM8
Type           : DDR2 FB-DIMM - Synchronous
Size           : 2048  MB
Â
If you don’t see any errors (it could take some time for errors to appear there), you could also check your System Events Log (SEL) by running the following command:
racadm getsel
3. Change your current directory to c:\Program Files\Dell\SysMgt\omsa\bin:
cd c:\Program Files\Dell\SysMgt\omsa\bin
4. Run the following command to reset ECC errors counters:
dcicfg32 command=clearmemfailures
It should print:
clearing failures using mask: 31
DIMM1 : ok
DIMM2 : ok
DIMM3 : ok
DIMM4 : ok
DIMM5 : ok
DIMM6 : ok
DIMM7 : ok
DIMM8 : ok
5. Run the following command to check if everything OK:
omreport chassis 
The result should be similar to:
Main System Chassis
SEVERITY : COMPONENT
Ok       : Fans
Ok       : Intrusion
Ok       : Memory
Ok       : Power Supplies
Ok       : Processors
Ok       : Temperatures
Ok       : Voltages
Ok       : Hardware Log
Ok       : Batteries
Â
6. To clear your system events log, run the following command:
racadm clrsel
Â
That's it! Errors have been cleared, but it doesn't guarantee that they will not appear again. Basically, these steps do nothing but reset the error counters to their initial value.